Failure patterns

Outages caused by config changes

A configuration change causes an outage when the new setting does what it was told, at a scope nobody meant. A permission, a network control, or a replica cap takes effect, and the width of that effect is the failure.

Supabase lost us-east-2 for 3 hours and 42 minutes on February 12, 2026, from 21:12 UTC. A monitoring deployment created VpcBlockPublicAccessOptions in block-bidirectional mode and enabled region-wide VPC Block Public Access. More than 20 production subnets had no exclusion, so internet-gateway traffic stopped. The team called it a pipeline configuration error, not an AWS outage.

On November 18, 2025, a Cloudflare ClickHouse permissions change at 11:05 UTC made implicit table access explicit. A Bot Management query of system.columns had no database filter and returned rows from both the default database and r0. The feature file grew past the proxy's 200-feature limit, an unhandled Result::unwrap() panicked the core proxy, and the edge returned HTTP 5xx. The file regenerated every five minutes during rollout, so the failure flickered and first looked like a denial-of-service attack.

Buildkite on August 25, 2026 shows a cap left in place. High maxReplica counts let a 22:44 UTC deploy exhaust node headroom and request still more pods. The evidence calls that runaway a direct result of the configuration, before the churn took out CoreDNS. One of three Claude bugs was a TPU misconfiguration deployed on August 25, 2025. It assigned token probabilities incorrectly and was rolled back on September 2.

Cases in this pattern

  1. AI & Automation

    Claude Infrastructure Degradation Triple-Bug Postmortem

    Between August and September 2025, three overlapping infrastructure bugs intermittently degraded Claude's response quality across multiple hardware platforms. Users reported nonsensical outputs, incorrect language characters, and syntax errors that appeared random and inconsistent. The issues proved difficult to diagnose because each bug produced different symptoms at different rates on different platforms, and the team's internal evaluations did not capture the degradation users were experiencing. Root causes included a context-window routing error, a TPU output corruption misconfiguration, and a latent XLA:TPU compiler bug triggered by a sampling code rewrite.
  2. Cloud Infrastructure

    Cloudflare outage on November 18, 2025: ClickHouse permissions change doubled Bot Management feature file and panicked the core proxy

    A routine ClickHouse permissions change caused a metadata query to return duplicate rows, doubling the Bot Management ML feature file. When the oversized file propagated to Cloudflare's global edge, the core proxy's Bot Management module hit its 200-feature preallocated limit and panicked via an unhandled Result::unwrap(), returning HTTP 5xx network-wide. The intermittent failure pattern (good/bad files every five minutes during the ClickHouse rollout) initially led engineers to suspect a hyper-scale DDoS attack.
  3. Networking

    Supabase us-east-2 Regional Outage: Monitoring-Service Deployment Accidentally Enabled VPC Block Public Access Region-Wide

    On February 12, 2026, at 21:12 UTC, Supabase suffered a 3-hour-42-minute outage in us-east-2 when a monitoring service deployment inadvertently enabled AWS VPC Block Public Access region-wide, blocking all internet gateway traffic. The investigation faced multiple red herrings: alarms triggered on shared services in a different region that were symptoms, not causes, and a lack of pre-production parity (pre-prod did not cover us-east-2) masked the blast radius. The turning point came when the team correlated timestamps of new network resource creation in us-east-2 with the exact start of the outage.
  4. Cloud Infrastructure

    Buildkite Service Disruption: CoreDNS Overload During ECS-to-EKS Migration

    A routine application deploy triggered a runaway autoscaling cascade in Buildkite's EKS cluster, generating a surge of DNS queries that overwhelmed the fixed-size CoreDNS deployment. All three CoreDNS pods exhausted their 512 MiB memory limits and were OOMKilled, causing a site-wide DNS resolution failure that broke service discovery for every customer-facing service. The outage lasted 29 minutes and was resolved by scaling CoreDNS from 3 to 12 replicas with 2 GiB memory each. Post-incident analysis revealed that a defective monitoring query had masked a months-long upward trend in CoreDNS latency, causing the planned autoscaling to be deprioritized.